It can be installed on any folder-gluer. Precise and versatile. Driven by microprocessor. Automatic
recovery of machine speed variances. Conceived for performances which go well beyond those of a
simple packs counter: Displays and prints production datas, four auxiliary input will permit
integration to machine PLC for the display of up to 15 messages on causes of machine stop.
Perform blanks random marking for quality control according to european norms ISO 2859.
Rack in aluminium treated with a layer in PVC.
Dimentions: height x length x depth, in mm. 133 x 341 x 304.
Front panel in polycarbonate with untidust soft touch keys. High luminosity signalling LED.
2 LCD backlit displays. Provided with a high resolution machine speed detector and necessary
electronics for the recovery of machine speed variances. Selection, via software, of all required
data inputs as well as of current production informations and results wanted to display or print.
Content of available software menu:
| Functions selection: |
| Counting |
Activated |
:1 |
Disactivated |
:0 |
| Mark/kick device drop |
Marker |
:1 |
Kicker |
:0 |
| Kicker |
Pneumatic |
:1 |
Magnetic |
:0 |
| Cartons feed photocell |
Activated |
:1 |
Disactivated |
:0 |
| Test (while adj.) mark/kick device |
Activated |
:1 |
Disactivated |
:0 |
| Squaring photocell |
Activated |
:1 |
Disactivated |
:0 |
| Test (while adj.) random marking |
Activated |
:1 |
Disactivated |
:0 |
| Random marking |
Activated |
:1 |
Disactivated |
:0 |
| Random to apply ISO |
Tables |
:1 |
Manual |
:0 |
| Print |
PC net |
:1 |
Printer |
:0 |
| Visualize |
Total |
:1 |
Riduced |
:0 |
| Data input: |
from |
to |
units |
| Blanks per pack |
2 |
254 |
pieces |
| Timing magnetic kicker |
20 |
50 |
milliseconds |
| Timing pneumatic kicker |
20 |
200 |
milliseconds |
| Timing marker (drop marking) |
20 |
200 |
milliseconds |
| Distance photocell/mark-kick device |
5 |
4.000 |
millimetres |
| Collector belt (in absence of blanks) |
2 |
255 |
centimetres |
| Squaring length |
2 |
127 |
centimetres |
| Production lot size |
2 |
16.000 |
pieces x 1000 |
| Random marking: manual setting |
32 |
2.000 |
pieces |
| Random marking: ISO tables |
1 |
3 |
tables |
| Serial port: baud rate |
1.200 |
38.400 |
bit/sec. |
| Serial port: bit number |
7 |
8 |
bit |
| Serial port: stop bit |
1 |
2 |
bit |
| Serial port: parity bit |
0 |
1 |
bit |
Personalizations:
| Language: |
Italian, English (optional, on request, French, Spanish, German, etc). |
| Set date/hour: |
hour/minutes; day/month/year (Y2K bug free). |
| Company name: |
alphanumeric characters. |
| Error messages: |
4 BCD input lines for the display of up to 15 causes of machine stop. These same 4 BCD
inputs may, alternatively, be used for the counting of bar code reading errors and
glue errors with the recorded total individual time of derived machine down time. |